ANITA MEDICAL SYSTEMS PVT. LTD.
FCR Capsula X
To inquire, Select Product/s & Click on
Product Code :
01
[Select]
Product Specification
FCR Capsula
Fujifilm FCR Capsula X Specifications
Standard Components
FCR capsula X image reader (Model: CR-IR 357)
AC power coad
Other system components
IP cassette type CC, LC
CR console
Image recorder: Drypix 1000/300/4000/7000
Supplies
Imaging Plate
ST-VI
14" x 17" , 14" x 14", 10" x 12", 8" x 10", 15 x 30cm (Inch settings)
35 x 43 cm, 35 x 35cm, 24 x 30cm, 18 x 24 cm, 15 x 30 cm (Metric settings)
IP Cassette
Type CC
14" x 17" (35.4 x 43 cm), 14" x 14" (35.4 x 35.4 cm), 10" x 12", 8" x 10", 24 x 30cm, 18 x 24 cm, 15 x 30cm
Type LC
35.4 x 124.5cm, 35.4 x 101.7 cm, 35.4 x 83 cm, 25.2 x 58 cm, 24 x 57cm
Time Required for IP Feed / Load
IP Type
Required Time
14" x 17" (35 x 43 cm)
Approx. 82 sec.
14" x 14" (35 x 43 cm)
Approx. 72 sec.
10" x 12"
Approx. 66 sec.
8" x 10"
Approx. 53 sec.
24 x 30 cm
Approx. 66 sec.
18 x 24 cm
Approx. 50 sec.
15 x 30 cm
Approx. 65 sec.
The time required for changing the cassette is assumed to be 0 (zero) seconds.
The time required for image erasure is assumed to be for exposure performed at 25mR of X-ray dose.
Processing Capacity
IP Type
When connected to
Drypix 7000/CR Console Pluse
14" x 17" (35 x 43 cm)
Approx. 43 IPs/hr.
14" x 14" (35 x 35 cm)
Approx. 50 IPs/hr.
10" x 12"
Approx. 54 IPs/hr.
8" x 10"
Approx. 67 IPs/hr.
24 x 30 cm (ST)
Approx. 54 IPs/hr.
18 x 24 cm (ST)
Approx. 72 IPs/hr.
15 x 30 cm (ST)
Approx. 55 IPs/hr.
The time required for changing the cassette is assumed to be 0 (zero) seconds
The time required for image erasure is assumed to be for exposure performed at 25 mR of X-ray dose.
Time to print on Drypix 7000 through network via CR Console
Approx. 135 sec. (35 x 43 cm).
Time To Display on CR Console
35 x 43 cm: Approx. 52 sec.
18 x 24 cm: Approx. 31 sec.
Number of Stackers: 1
Reading gray scale: 12 bits
Network: 10 Base T /100 Base TX
Dimensions (W x D x H): 590 x 380 x 810 mm (23" x 15" x 32")
Weight: 99 kg (218 Ibs.)
Power Supply Conditions
Single phase 50-60Hz
120-240V ±10%
5A (max).
Environmental Conditions
Operating Conditions
Temperature: 16-30°C
Humidity: 15-80%RH (No dew condensation)
Non-operating conditions
Temperature: 0.45°C
Humidity: 10-90%RH (No dew condensation).
Other Products in 'Fuji CR' category
FCR Profect CS
Medical Dry Laser Imager
Fuji Computed Radiography
Medical Dry Imager
<< Back
Contact Details
ANITA MEDICAL SYSTEMS PVT. LTD.
3A/4, Commercial Block, Ram Apartments, 4th Lane, Pandurangwadi, Goregaon (East), Mumbai - 400063, Maharashtra, India
Phone:
91-22-28741625/28768649/28747542/28712882